The AST-100TSY is a simple solution to viscosity control when special features or elaborate operator interfaces are not required.
The AST-100TSY — coupled to a simple, remote, loop-powered indicator scaled in engineering units — allows an operator to make better and faster decisions because he/she does not have to rely on unreliable or inconsistent measurement techniques.
The AST-100TSY is also “ideal” for low cost, seamless integration of viscosity measurements into factory floor, automated control systems (PC, PLC, DCS, etc). Our new AST-100TSY includes a powerful, digital communication feature (Modbus RTU) that allows up to 10 viscometers to be networked into a single, reliable, multi-station, viscosity measurement system. It is easily integrated into a process controller using a single twisted pair wire.
Optional AST-300SY Single-Station Controller
The AST-100TSY is also “ideal” for low cost, seamless integration of viscosity measurements into factory floor, automated control systems (PC, PLC, DCS, etc).
Our new AST-100TSY includes a powerful, digital communication feature (Modbus RTU) that allows up to 10 viscometers to be networked into a single, reliable, multi-station, viscosity measurement system. It is easily integrated into a process controller using a single twisted pair wire.
Optional AST-400SY Multi-Station Controller
AST-100 Viscosity Sensor Specifications
Measurement Type: | Torsionally oscillating probe |
Measurement Range: | 0 to 3,300 cSt using an NIST traceable, Newtonian fluid measured at 25°C |
Process Connections: | 1″ Male NPT standard, (1½» tri-clamp or 3A design, optional) |
Repeatability: | ± 1.0% of reading |
Wetted Surfaces: | 316L stainless steel |
Sensor O-Ring: | Isolast for probe, Viton for chamber housing (EDPM or Kalrez®, optional) |
Temperature (fluid): | -4° to 248°F (-20° to 120°C) |
AST-100TSY Transmitter Specifications
Viscosity Ranges (cSt) (field selectable): | 0—10, 0—50, 0—100, 0—250, 0—500, 0—1000, 0—1500, 0—2000, 0—3300 |
Maximum Resolution: | Analog: ± 0.05% of full scale Digital: ± 0.1 cSt |
Analog Output (2): | 4—20 mA (non-isolated)
CH1 = viscosity CH2 = temperature |
Serial Port (2): | Port 1 = RS232, simplex, read
only, Port 2 = ½ Duplex RS485, Modbus RTU driver |
Temperature Range (ambient): | 32° to 104°F (0° to 40°C) |
Electronics Packaging: | Wall mount, NEMA-4 (IP65), 8″ x 8″ x 6″ (203 x 203 x 152mm) |
Electrical Area Rating: | NEMA-4, NEMA-7 or ATEX are optional |
Interconnecting Cable: | 25 ft (7.6m) standard: 50 ft (15.2m), 75 ft (22.8m) and 100 ft (30.4m) optional |
Supply Voltage: | 115V/60 Hz or 230V/50 Hz (± 10% max), power draw <1 amp |